Gasanalyse for cementfabrikker

Calciner

Calciner Gas Analysis

The KilnLoq calciner gas analysis system can optimize the calciner pyro-process and prevent process interlocks from shutting down operation.

  • About
  • Downloads

To gain this, the gas analyser must be on-line all the time providing consistent, comparable and accurate data of the calciner operation. In the calciner, we take advantages of the unique KilnLoq probe developed by FLSmidth. The probe configuration is identical to the KilnLoq probe used in the kiln inlet – however the probe length is shorter in the calciner.

 

Benefits

Experience shows that an unattended burning process in the calciner easily may get out of balance, creating unwanted high levels of Carbon Monoxide (CO). This may trigger the interlocking to shut down kiln and calciner burners causing a production stop that could have been avoided. Furthermore, if the calciner is of a type which is capable of producing a consistent low level of CO in order to reduce the final NOX emission, the calciner gas analysis system becomes a necessary measurement to facilitate this. In any case, the cost of shutting down the production and starting it up again is costly both in lost production and in wasted fuel.

To illustrate the importance of this - a kiln producing e.g. 5000 ton clinker/day at a global average market price of 56$/ton clinker will loose approx. 11,650$/hour during a kiln stop on that account alone. A calciner analysing system only has to reduce this number of stop hours by approx. 15-20 before the investment is returned.

The combustion process of the calciner reacts faster and is even more sensitive to changes in the combustion process than the kiln. The operation stability of a calciner is under great influence of changing gas flow and the actual oxygen content. By being on-line with the combustion process in the calciner not only the operation of the calciner can be guarantied but also the over-all kiln operation can be optimised for the combined optimal operation of kiln, calciner, burner, cooler and ID-fan.

Stable calciner combustion is what calciner gas analysis is really all about. The innovative KilnLoq probe is the only probe on the market capable of achieving this - day after day, at a minimum of maintenance and with an unprecedented high run factor.

To learn more about our capabilities in calciner gas analysis and the KilnLoq probe – please download the brochure or contact a sales representative.

  • Main Office

    FLSmidth A/S
    Cement Technologies & Corporate Matters
    Vigerslev Allé 77
    2500 Valby
    DENMARK
    Tel: +45 36 18 10 00
    Fax: +45 36 44 11 46
    info@flsmidth.com
  • Main Office

    FLSmidth Inc.
    Cement Projects Americas
    2040 Avenue C
    Bethlehem, PA 18017
    USA
    Tel: +1 610 264 6011
    Fax: +1 610 264 6170
    info-us@flsmidth.com
  • Main Office

    FLSmidth Pvt. Ltd
    Cement and Minerals Projects India
    FLSmidth House, 34, Egatoor, Kelambakkam
    (Rajiv Gandhi Salai – Chennai)
    Tamil Nadu – 603 103
    INDIA
    Tel: +91 44 4748 1000 / 2741 1000
    Fax: + 91-44-2747 0301/0302
    indiainfo@flsmidth.com
  • Main Office

    FLSmidth Salt Lake City, Inc.
    Minerals Processing
    7158 S. FLSmidth Drive
    Midvale, UT 84047-5559
    USA
    Tel: +1 801 871 7000
    Fax: +1 801 871 7001
    info.slc@flsmidth.com
  • Main Office

    FLSmidth Wadgassen
    Material Handling Technologies
    Karl Koch Str. 1
    D-66787 Wadgassen
    GERMANY
    Tel: +49 6834 4700
    Fax: +49 6834 470-339
    wadgassen@flsmidth.com

Please contact me

Please fill out this form

Contact Data
Name
Remember name
Email
Remember phone/email
Country
Remember Country
Subject Matter
Remember subject
I would like to be contacted by:
You must choose at least one point of contact
For other contacts, please use the contact information displayed on the page.
Contact me

Thank you for contacting FLSmidth. We will get back to you as soon as possible.

We will contact you as soon as possible